Commercial · Server and equipment rooms
Cooling system service for server and equipment rooms in Montreal
Repairs, installation and preventive maintenance for cooling systems serving server rooms, equipment rooms and other temperature-sensitive spaces. We inspect equipment, document its condition and help plan maintenance and replacements around your site’s operating needs.

- 19Rooms under contract
- 24/7Emergency service
- Scheduled maintenanceService planned for your equipment and operations
- Service reportsEquipment condition, readings and completed work documented
What planned maintenance covers
Six areasScheduled inspections
Dedicated cooling units inspected on a set schedule, with filters, coils, drains, controls and operating readings checked at each visit.
Avoiding downtime
Worn parts, falling performance and small leaks found during scheduled visits, before they turn into an unplanned shutdown.
Year-round cooling
Winter cooling controls checked where the room needs cooling all year, including when it is cold outside.
Condensate and water
Drains, pumps and pans checked so water stays away from racks and equipment.
Visits around your operation
Visit frequency and timing set by the site’s operating requirements, from 2 to 52 visits per year.
Service reports
Readings, findings and photos recorded after every visit, so changes in performance can be tracked over time.
What it costs
Montreal & West Island, 2026Commercial service calls start at $500. Commercial rates can differ based on the equipment, access requirements and scope of work. We explain the applicable charges when arranging service.
Questions buyers ask
Temperature alarms route to your team and our dispatch, with escalation agreed in writing. Equipment-room calls are treated as emergencies.
If an outage costs more than the second unit, yes. We plan lead-lag rotation verified on every visit.
With low-ambient kits, yes. A room that only cools above freezing outside is a common and expensive oversight.
Drainage routed away from racks with leak detection and float switches tested on schedule.
18 to 27 °C and 40 to 60% relative humidity at the intake, per ASHRAE. We measure at the rack, not at the wall thermostat.
Yes. Temperature and humidity at the rack with alarms to your phone and to our dispatcher, so the room is not discovered warm in the morning.
Yes, both, plus ductless units serving small rooms. Coil, filter, humidifier and condensate on a quarterly cycle.
We can arrange portable cooling. It holds the room while the permanent repair is scheduled properly.